Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46.170
Filtrar
1.
Langenbecks Arch Surg ; 409(1): 124, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615148

RESUMO

PURPOSE: Gastrointestinal disorders frequently necessitate surgery involving intestinal resection and anastomosis formation, potentially leading to severe complications like anastomotic leakage (AL) which is associated with increased morbidity, mortality, and adverse oncologic outcomes. While extensive research has explored the biology of anastomotic healing, there is limited understanding of the biomechanical properties of gastrointestinal anastomoses, which was aimed to be unraveled in this study. METHODS: An ex-vivo model was developed for the biomechanical analysis of 32 handsewn porcine end-to-end anastomoses, using interrupted and continuous suture techniques subjected to different flow models. While multiple cameras captured different angles of the anastomosis, comprehensive data recording of pressure, time, and temperature was performed simultaneously. Special focus was laid on monitoring time, location and pressure of anastomotic leakage (LP) and bursting pressures (BP) depending on suture techniques and flow models. RESULTS: Significant differences in LP, BP, and time intervals were observed based on the flow model but not on the suture techniques applied. Interestingly, anastomoses at the insertion site of the mesentery exhibited significantly higher rates of leakage and bursting compared to other sections of the anastomosis. CONCLUSION: The developed ex-vivo model facilitated comparable, reproducible, and user-independent biomechanical analyses. Assessing biomechanical properties of anastomoses offers an advantage in identifying technical weak points to refine surgical techniques, potentially reducing complications like AL. The results indicate that mesenteric insertion serves as a potential weak spot for AL, warranting further investigations and refinements in surgical techniques to optimize outcomes in this critical area of anastomotic procedures.


Assuntos
Fístula Anastomótica , Mesentério , Animais , Suínos , Fístula Anastomótica/prevenção & controle , Anastomose Cirúrgica , Mesentério/cirurgia , Técnicas de Sutura , Cicatrização
2.
Ann Plast Surg ; 92(4S Suppl 2): S150-S155, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556665

RESUMO

BACKGROUND: Use of the absorbable deep dermal stapler in wound closure has become more common in plastic surgery because of its possible reduction in operative times and subsequent decrease in operative room costs. In this study, we examine the effects of this stapler on operative times and postoperative complications in bilateral reduction mammaplasties. METHODS: A retrospective, observational cohort study was conducted via electronic chart review on patients who underwent bilateral reduction mammaplasties. Patients were stratified by wound closure method. One group was closed with sutures only, and in the other group, deep dermal staples were used during closure of the inframammary fold incision. Incidences of patient comorbidities and postoperative complications were compared. In addition, a financial cost analysis was performed. RESULTS: The final patient cohort included 62 patients. Operative time was reduced by an average of 21.8 minutes when using deep dermal staples during closure, compared with when closing solely with sutures (P = 0.032). When controlling for mass of breast tissue removed and type of pedicle, deep dermal staple closure still predicted a reduction of 26.5 (SE, 9.9) minutes in operative time (P = 0.010). Postoperative complications were not affected by wound closure method (odds ratio, 4.36; 95% confidence interval, 0.91-31.7, P = 0.087). Though not statistically significant, financial charge was decreased with usage of deep dermal staples (P = 0.34). CONCLUSIONS: Use of absorbable deep dermal staples produces a significant decrease in operative time for reduction mammaplasties with no increase in postoperative complication rates.


Assuntos
Mamoplastia , Técnicas de Sutura , Humanos , Mamoplastia/efeitos adversos , Duração da Cirurgia , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Infecção da Ferida Cirúrgica/etiologia , Suturas/efeitos adversos , Resultado do Tratamento , Feminino
5.
BMC Med Educ ; 24(1): 415, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627740

RESUMO

BACKGROUND: Suture knotting is the basis of surgical skills. In the process of surgical skills learning, the surrounding environment, especially the light, will affect the efficiency of learning. This study investigated the effect of optical environment on the learning of stitching and knotting skills. METHODS: A total of 44 medical students were randomly divided into four groups and participated in the study of suture knotting in four different optical environments. During the process, we assess objective pressure level by testing salivary amylase activity Likert scale and objective structured clinical examination (OSCE) was used to estimate the subjective psychological state and overall skill mastery in surgical suturing respectively. RESULTS: Under high illumination conditions (700 lx), the salivary amylase activity of the high color temperature group (6000 K) was significantly higher than that of the low color temperature group (4000 K) (p < 0.0001). Similarly, under low illumination (300 lx), the salivary amylase activity of the high color temperature group was also significantly higher than that of the low color temperature group (p < 0.05). The student under high illumination conditions (700 lx) and the low color temperature (6000 K) have an autonomy score between 37-45, which is significantly higher compared to the other three groups (p < 0.0001). Group 2 has an average OSCE score of 95.09, which were significantly higher than those of the other three groups (p < 0.05). CONCLUSION: High illumination combined with low color temperature is considered as the optimal training conditions, promoting trainees' optimism, reducing stress levels, and enhancing learning efficiency. These results highlight the pivotal role of light environment in improving the quality and efficiency of surgical skills training.


Assuntos
Aprendizagem , Exame Físico , Humanos , Amilases , Competência Clínica , Técnicas de Sutura/educação
6.
Khirurgiia (Mosk) ; (4): 29-37, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38634581

RESUMO

OBJECTIVE: To evaluate the short-term outcomes of mechanical and hand-sewn laparoscopic one-anastomosis mini-gastric bypass. MATERIAL AND METHODS: There were 233 patients who underwent laparoscopic one-anastomosis mini-gastric bypass. Short-term results were analyzed in groups of mechanical (the first group, n=108) and hand-sewn (the second group, n=125) gastrojejunostomy. No significant between-group differences in baseline data were detected (demographic characteristics, body mass index, comorbidity and previous abdominal surgeries). RESULTS: Surgery time and blood loss were similar in both groups. Intraoperative morbidity was 7.2-10.2% (p=0.485). All complications required no surgical conversion (Satava-Kazaryan grade I). Overall postoperative morbidity was 16.0-21.3% (p=0.314). Most events corresponded to Accordion grade I and had no significant effect on hospital-stay. CONCLUSION: This study revealed no significant differences in short-term outcomes after laparoscopic one-anastomosis gastric bypass with mechanical and hand-sewn gastrojejunostomy. Further study of long-term clinical outcomes is necessary.


Assuntos
Derivação Gástrica , Laparoscopia , Obesidade Mórbida , Humanos , Derivação Gástrica/métodos , Laparoscopia/métodos , Técnicas de Sutura/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Obesidade Mórbida/cirurgia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos
8.
J Cardiothorac Surg ; 19(1): 174, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576006

RESUMO

BACKGROUND: There is ambiguity in the literature regarding the continuous suture technique (CST) for aortic valve replacement (AVR). At our center, there has been a gradual shift towards CST over the interrupted pledgeted technique (IPT). This study aims at comparing outcomes for both techniques. METHODS: We performed a retrospective analysis of a single-center study of patients undergoing AVR between January 2011 and July 2020. Patients were divided into two groups: Continuous suture technique and interrupted pledget-reinforced sutures. The pre-operative and In-hospital clinical characteristics and echocardiographic hemodynamics (i.e. transvalvular gradients and paravalvular leakage) were compared between CST and IPT. RESULTS: We compared 791 patients with CST to 568 patients with IPT (median age: 73 and 74 years, respectively, p = 0.02). In CST there were 35% concomitant procedure vs. 31% in IPT (p = 0.16). Early mortality was 3.2% in CST versus 4.8% in IPT (p = 0.15), and a second cross-clamp due to a paravalvular-leak in 0.5% vs. 1.2%, respectively (p = 0.22). The CST was not associated with new-onset conduction-blocks mandating pacemaker implants(OR 1.07, 95% CI 0.54-2.14; P = 0.85). The postoperative gradients on echocardiography were lower in CST compared to IPT, especially in smaller annuli (peak gradients: 15.7mmHg vs. 20.5mmHg, in valve size < 23 mm, p < 0.001). CONCLUSIONS: The continuous suture technique was associated with lower postoperative gradients and shorter cross-clamp time compared to interrupted pledgeted technique. Differences in paravalvular leaks were non-significant, although slightly less in the continuous suture technique. There were no further differences in valve-related complications. Hence, continues suture technique is safe, with better hemodynamics compared to the interrupted pledgeted technique. This may be of clinical importance, especially in smaller size annular size.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Idoso , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Técnicas de Sutura , Resultado do Tratamento , Desenho de Prótese
9.
ANZ J Surg ; 94(4): 604-613, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38456319

RESUMO

BACKGROUND: Approach to enteric anastomotic technique has been a subject of debate, with no clear consensus as to whether handsewn or stapled techniques are superior in trauma settings, which are influenced by unique perturbances to important processes such as immune function, coagulation, wound healing and response to infection. This systematic review and meta-analysis compares the risk of anastomotic complications in trauma patients with gastrointestinal injury requiring restoration of continuity with handsewn versus staples approaches. METHODS: A comprehensive computer assisted search of electronic databases Medline, Embase and Cochrane Central was performed. Comparative studies evaluating stapled versus handsewn gastrointestinal anastomoses in trauma patients were included in this review. All anastomoses involving small intestine to small intestine, small to large intestine, and large intestine to large intestine were eligible. Anastomosis to the rectum was excluded. Outcomes evaluated were (1) anastomotic leak (AL) (2) a composite anastomotic complication (CAC) end point consisting of AL, enterocutaneous fistula (ECF) and deep abdominal abscess. RESULTS: Eight studies involving 931 patients were included and of these patients, data from 790 patients were available for analysis. There was no significant difference identified for anastomotic leak between the two groups (OR = 0.77; 95% CI 0.24-2.45; P = 0.66). There was no significant improvement in composite anastomotic complication; defined as a composite of anastomotic leak, deep intra-abdominal abscess and intra-abdominal fistula, in the stapled anastomosis group (OR = 1.05; 95% CI 0.53-2.09; P = 0.90). Overall, there was limited evidence to suggest superiority with handsewn or stapled anastomosis for improving AL or CAC, however this was based on studies of moderate to high risk of bias with poor control for confounders. DISCUSSION: This meta-analysis demonstrates no superiority improvement in anastomotic outcomes with handsewn or stapled repair. These findings may represent no effect in anastomotic outcome by technique for all situations. However, considering the paucity of information on potential confounders, perhaps there is a difference in outcome with overall technique or for specific subgroups that have not been described due to limited sample size and data on confounders. Currently, there is insufficient evidence to recommend an anastomotic technique in trauma.


Assuntos
Fístula Anastomótica , Técnicas de Sutura , Humanos , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/cirurgia , Grampeamento Cirúrgico , Anastomose Cirúrgica/métodos , Reto/cirurgia
10.
Am J Sports Med ; 52(5): 1308-1318, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38523475

RESUMO

BACKGROUND: The approach to managing the footprint area and reconstructing the tendon-bone interface (TBI) is critical for optimal healing. PURPOSE: To evaluate the outcomes of the semi-bone tunnel (SBT) technique using a double-row suture bridge combined with platelet-rich plasma (PRP) hydrogel for rotator cuff repair in a rabbit model. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 48 New Zealand White rabbits were divided into 4 groups. The supraspinatus tendons were severed at the footprint to create a rotator cuff tear model in the surgical groups. Rabbits were treated with the traditional onto-surface repair (control group), SBT technique (SBT group), and SBT technique combined with PRP hydrogel implantation (SBT+PRP group). The rabbits without surgery were the normal group. At 8 weeks after surgery, macroscopic observation, magnetic resonance imaging (MRI) and micro-computed tomography (µCT) examinations, histological evaluations, and biomechanical tests were performed to assess the curative effects of the given treatments. RESULTS: The MRI results showed that the repaired supraspinatus tendon presented a uniform signal, minimal inflammatory response, and the lowest signal-to-noise quotient value in the SBT+PRP group. The µCT results suggested that the SBT technique did not reduce the local bone mineral density in the TBI area compared with the onto-surface repair technique. The histological staining results showed that the regenerated TBI in the SBT+PRP group had a 4-layer structure similar to the natural tissue. The highest values for biomechanical properties were observed in the SBT+PRP group, and there was no significant difference between the SBT+PRP group and normal group. CONCLUSION: The SBT technique presented a better tendon-bone healing effect for rotator cuff tear in the rabbit model compared with the traditional onto-surface repair technique. The specimens in the SBT+PRP group had a similar TBI structure and biomechanical properties to the natural tissue. CLINICAL RELEVANCE: The SBT technique can be an alternative surgical approach for rotator cuff repair, especially for moderate to large tears and cases requiring scaffold implantation.


Assuntos
Plasma Rico em Plaquetas , Lesões do Manguito Rotador , Coelhos , Animais , Manguito Rotador/cirurgia , Manguito Rotador/patologia , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/patologia , Hidrogéis , Microtomografia por Raio-X , Cicatrização , Suturas , Fenômenos Biomecânicos , Técnicas de Sutura
11.
BMC Musculoskelet Disord ; 25(1): 246, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38539131

RESUMO

BACKGROUND: Shoulder disorders, particularly rotator cuff tears, are prevalent musculoskeletal conditions related to aging. Although the widely used suture anchor technique provides strong mechanical support to the tendon, it is associated with a risk of postoperative tendon retearing. The conventionally used titanium alloys can affect the interpretation of magnetic resonance imaging. Degradable magnesium alloys possess excellent biocompatibility, similar mechanical property to the bone, and stimulating bone formation ability from Mg2+. The purpose of this experiment was to develop innovative magnesium-based suture anchors to enhance rotator cuff repair by improving fixation materials, and to evaluate their feasibility in a goat model. METHODS: We developed fluoridized ZK60 suture anchors as the implantation material for two goats, who underwent rotator cuff repair surgery on both shoulders. Computed tomography (CT) and histological analysis were performed at 12 weeks postoperatively, and the results were compared between the magnesium and titanium alloy groups. Additionally, a hematological examination was conducted, which included assessments of red blood cells, white blood cells, platelets, coagulation function, liver function, kidney function, and magnesium ion concentration. RESULTS: The 12-week postoperative CT images showed intact MgF2 ZK60 suture anchors, effectively reconnecting the infraspinatus tendon to the humeral head. The anchors became less visible on CT scans, indicating absorption by surrounding tissues. New bone formation in the MgF2 group surpassed that in the Ti group, demonstrating superior osseointegration. The similarity between cortical bone and magnesium reduced stress-shielding and promoted bone regeneration. Histological analysis revealed successful tendon healing with MgF2 anchors, while the Ti group showed discontinuous interfaces and reduced collagen secretion. Hematological examination showed stable liver, renal function, and magnesium ion levels. CONCLUSIONS: The findings indicate that MgF2-coated suture anchors are feasible for rotator cuff repair and potentially other orthopedic applications. We hope that magnesium alloy anchors can become the solution for rotator cuff tendon repair surgery.


Assuntos
Lesões do Manguito Rotador , Ombro , Animais , Ombro/cirurgia , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Manguito Rotador/patologia , Âncoras de Sutura , Magnésio , Cabras , Titânio , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/patologia , Ligas , Técnicas de Sutura , Artroscopia/métodos
12.
J Cardiothorac Surg ; 19(1): 158, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38539222

RESUMO

BACKGROUND: Functional tricuspid regurgitation may arise from left heart valve diseases or other factors. If not addressed concurrently with primary surgical intervention, it may contribute to increased morbidity and mortality rates during the postoperative period. This study investigates the impact of various repair techniques on crucial factors such as systolic pulmonary artery pressure (SPAP), tricuspid valve regurgitation, and New York Heart Association (NYHA) functional capacity class in the postoperative period. MATERIALS AND METHODS: From April 2007 to June 2013, 379 adults underwent open-heart surgery for functional tricuspid regurgitation. Patients were categorized into four groups: Group 1 (156) with De Vega suture annuloplasty, Group 2 (60) with Kay suture annuloplasty, Group 3 (122) with Flexible Duran ring annuloplasty, and Group 4 (41) with Semi-Rigid Carpentier-Edwards ring annuloplasty. Demographic, clinical, operative, and postoperative data were recorded over a mean follow-up of 35.6 ± 19.1 months. Postoperative SPAP values, tricuspid regurgitation grades, and NYHA functional capacity classes were compared among the groups. RESULTS: No statistically significant differences were observed among the groups regarding age, gender, preoperative disease diagnoses, history of previous cardiac operations, or echocardiographic characteristics such as preoperative ejection fraction, SPAP, and tricuspid regurgitation. Hospital and intensive care unit length of stay and postoperative complications also showed no significant differences. However, patients in Group 3 exhibited longer Cardio-Pulmonary Bypass duration, cross-clamp duration, and higher positive inotrope requirements. While the mortality rate within the first 30 days was higher in Group 1 compared to the other groups (p: 0.011), overall mortality rates did not significantly differ among the groups. Significant regression in functional tricuspid regurgitation and a notable decrease in SPAP values were observed in patients from Group 3 and Group 4 (p: 0.001). Additionally, patients in Group 3 and Group 4 showed a more significant reduction in NYHA functional capacity classification during the postoperative period (p: 0.001). CONCLUSION: Among the repair techniques, ring annuloplasty demonstrated superiority in reducing SPAP, regressing tricuspid regurgitation, and improving NYHA functional capacity in functional tricuspid regurgitation repairs.


Assuntos
Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Adulto , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Valva Tricúspide/cirurgia , Valva Mitral/cirurgia , Técnicas de Sutura
13.
Int Wound J ; 21(3): e14751, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38472132

RESUMO

Pharyngocutaneous fistula (PCF) is a major complication after total laryngectomy, with significant morbidity and mortality. Whether mechanical stapler closure of the pharynx reduces fistula rates compared to hand-sewn techniques remains unclear. We conducted an updated systematic review and meta-analysis to clarify this question. Five databases were systematically searched from inception through November 2023 for studies comparing stapler versus suture closure for fistula outcomes after laryngectomy. Odds ratios (OR) were pooled using random-effects models and fixed-effects models. Subgroup and sensitivity analyses were performed. Risk of bias was appraised using NHLBI tools. Nine studies with 803 patients were included. Mechanical closure significantly reduced fistula incidence versus suture closure (OR = 0.57, 95% CI 0.34-0.95, p = 0.03). Subgroup analysis found that stapling's protective effect varied by patient age, country/region, linear stapler size and female percentage. Stapling reduced fistula odds by 80% in the Turkey subgroup (OR = 0.20, 95% CI 0.09-0.50) but showed no benefit in other regions. Patients <60 years showed an 84% fistula reduction with stapling (OR = 0.17, 95% CI 0.06-0.45), whereas older subgroups did not. Linear stapler size of 60 mm significantly reduced fistula occurrence while 75 mm did not. There was no evidence that low female percentage mitigated stapling benefits. Mechanical stapler closure after total laryngectomy meaningfully reduces the likelihood of postoperative PCF formation compared to hand-sewn closure, especially for patients younger than 60 years old. The absolute risk reduction supports its utility to prevent this complication.


Assuntos
Fístula Cutânea , Doenças Faríngeas , Técnicas de Fechamento de Ferimentos , Humanos , Fístula Cutânea/etiologia , Fístula Cutânea/cirurgia , Laringectomia/efeitos adversos , Doenças Faríngeas/etiologia , Doenças Faríngeas/cirurgia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Técnicas de Sutura
14.
Int J Surg ; 110(3): 1367-1375, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38484258

RESUMO

BACKGROUND: A diverting loop ileostomy (DLI) is performed in laparoscopic anterior rectal resection (LAR) surgery at high risk of anastomotic fistula. Minimally invasive surgery promotes postoperative recovery and cosmetics. To reduce abdominal trauma, specimen extraction through stoma incision (EXSI) is usually performed to avoid auxiliary abdominal incision with enlarged stomal incision. The traditional suture method (TSM) reduces the incision size by suturing the ends of the enlarged incision, leading to peristomal incisions and a higher risk of stomal complications. The study aimed to introduce the dumpling suture method (DSM) of PLI and compare this new method with TSM. MATERIALS AND METHODS: The authors propose a novel stoma suture technique, which utilized a method of skin folding suture to reduce the enlarged incision size. A retrospective analysis was conducted on 71 consecutive patients with rectal cancer who underwent LAR-DLI with EXSI, and the intraoperative details and postoperative outcomes of the two groups were measured. RESULTS: The DSM group showed a lower stomal complication rate (10.3 vs. 35.7%, P=0.016) than that of the TSM group. The scores of DET (Discoloration, Erosion, Tissue overgrowth), stomal pain, quality of life were all significantly lower in DSM group than in TSM group. In multivariate analysis, DSM was an independent protective factor for stoma-related complications. Operative time, time to first flatus, defecation and eat, nonstomal related postoperative complications were similar in both groups. CONCLUSION: DSM utilizes a method of skin folding suture to reduce the enlarged incision size, which is safe and effective in reducing the incidence of peristomal skin infections and stomal complications. This procedure offers a novel suturing approach for loop ileostomy with enlarged incision, effectively reducing the postoperative trauma and incidence of stomal complications.


Assuntos
Laparoscopia , Neoplasias Retais , Ferida Cirúrgica , Humanos , Ileostomia/métodos , Estudos Retrospectivos , Estudos de Coortes , Qualidade de Vida , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Neoplasias Retais/cirurgia , Anastomose Cirúrgica/efeitos adversos , Ferida Cirúrgica/complicações , Técnicas de Sutura/efeitos adversos , Suturas/efeitos adversos
15.
Acta Chir Plast ; 65(3-4): 147-149, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38538302

RESUMO

While fasciotomy is the only urgent treatment option for compartment syndrome, the resulting open wound leaves room for complications. Closure of the wound can be done by different techniques, including split-thickness skin grafts, negative pressure therapy, an absorbable barbed suture system and a cable ties system. The aim of this paper is to demonstrate how a combined application of these methods can reduce their respective individual disadvantages. Our combined method was tried in two patients, one with an open tibial fracture and the other who underwent ulnar nerve reparation. Both patients started exhibiting signs of compartment syndrome within 3 hrs after surgery. Firstly, absorbable barbed suture systems were positioned with the running intradermal technique. Following this the cable ties were inserted and the limb in question was placed in an elevated position. Complete closure of the patient's wounds was achieved within 2 weeks without complications. This result is a testament to the added benefit of a combination of these methods in comparison with the results they produce individually.


Assuntos
Síndromes Compartimentais , Fasciotomia , Humanos , Técnicas de Sutura , Transplante de Pele , Suturas , Síndromes Compartimentais/cirurgia
16.
Medicine (Baltimore) ; 103(11): e37533, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38489705

RESUMO

OBJECTIVE: To investigate the effect of Bakri balloon tamponade (BBT) combined with different suture methods on preventing postpartum hemorrhage in women with pregnancy-induced hypertension (PIH) undergoing cesarean delivery (CD). METHODS: This randomized, double-blind, controlled trial was conducted at The First Affiliated Hospital of Xingtai Medical College from October 2020 to June 2023. Patients with PIH who had persistent bleeding after CD and were unresponsive to uterine contractions, sutures, or uterine disconnection procedures were eligible participants. Eligible participants were randomly assigned to control and study groups, with 50 patients in each group. The control group used BBT combined with B-lynch uterine compression sutures, while the study group used BBT combined with modified Hayman suture. Intraoperative and postoperative bleeding and changes in vital signs were compared between the 2 groups. Moreover, changes in inflammation levels, coagulation function, and sex hormone levels were compared between the 2 groups before and after surgery. RESULTS: A total of 122 patients with persistent bleeding after CD were recruited, of whom 22 were excluded (16 cases of uterine contractions and/or local uterine myometrial sutures for hemostasis, 4 cases of preoperative uterine artery embolization, and 2 cases of uterine malformations). The intraoperative blood loss, postoperative blood loss at 2 hours, postoperative blood loss at 24 hours, and decrease in red blood cell and hemoglobin in the study group were significantly lower than those in the control group (P < .05). After surgery, the levels of inflammation, coagulation function, and sex hormone in both groups improved compared to before surgery, and the study group was significantly better than the control group (P < .05). In addition, the incidence of postoperative adverse events in the study group was significantly lower than that in the control group (P < .05). CONCLUSIONS: The hemostatic effect of BBT combined with B-lynch uterine compression sutures is comparable to that of BBT combined with modified Hayman suture for postpartum hemorrhage in pregnant women with PIH undergoing CD, but the latter has less blood loss, attenuated inflammatory response, reduced impact on coagulation function and ovarian function, and a lower incidence of adverse events.


Assuntos
Hipertensão Induzida pela Gravidez , Hemorragia Pós-Parto , Tamponamento com Balão Uterino , Feminino , Humanos , Gravidez , Hormônios Esteroides Gonadais , Hipertensão Induzida pela Gravidez/cirurgia , Inflamação/complicações , Hemorragia Pós-Operatória/cirurgia , Hemorragia Pós-Parto/etiologia , Hemorragia Pós-Parto/prevenção & controle , Estudos Retrospectivos , Técnicas de Sutura , Suturas , Tamponamento com Balão Uterino/métodos
17.
BMC Ophthalmol ; 24(1): 112, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454351

RESUMO

INTRODUCTION: Severe congenital ptosis poses a complex challenge for oculoplastic surgeons, requiring meticulous surgical intervention to restore eyelid function and improve aesthetic outcomes mainly by using frontalis sling approach. A crucial issue in frontalis sling surgeries is the sustainability of effect. PURPOSE: This retrospective study reports the outcomes of two surgical techniques for treating severe congenital ptosis in the paediatric age group: Silicon rods ptosis sling and a novel technique involving the use of Silicon rods with green braided polyester (Ethibond) sutures to secure the rods in place "sling for the sling". METHODS: The medical records of children who underwent frontalis suspension were reviewed in a retrospective fashion. We identified two groups; the first group (20 patients: 35 eyelids) had the traditional frontalis suspension surgery using silicone suspension set, the second group (14 patients: 25 eyelids) was operated using the new "sling for sling" technique. We used the postoperative marginal reflex distance-1 (MRD-1) as the primary outcome measure while the frequency of both wound related complications and recurrence were considered as secondary outcome measures. Post operative data were collected and compared after 1 month, 6 months, 12 months, and 18 months. RESULTS: Preliminary results indicate promising outcomes for both techniques, with significant improvement in eyelid elevation observed in both groups. However, the novel technique using Silicon rods with Ethibond sutures demonstrated enhanced sustainability, leading to a more durable outcome with significantly less recurrence. CONCLUSION: This study highlights the potential benefits of the novel technique in treating severe congenital ptosis and introduces an innovative approach to Silicone rods fixation to achieve a long-term corrective effect.


Assuntos
Blefaroplastia , Blefaroptose , Criança , Humanos , Blefaroplastia/métodos , Estudos Retrospectivos , Silício , Técnicas de Sutura , Blefaroptose/cirurgia , Blefaroptose/congênito , Silicones , Músculos Oculomotores/cirurgia , Resultado do Tratamento
18.
J Wound Care ; 33(Sup3a): lxi-lxviii, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38457269

RESUMO

OBJECTIVE: The use of 2-octyl cyanoacrylate with polyester mesh (OCA-M) has become common in total hip and knee arthroplasty (THA, TKA). We aimed to compare the safety and cosmetic outcomes between OCA-M and standard suture techniques and staples, and determine whether OCA-M can safely be used for TKA. METHOD: Inclusion criteria were patients who underwent THA or TKA from January 2010 to October 2011 (Suture group), November 2011 to August 2013 (Staple group), March 2017 to September 2018 (OCA-M group). Exclusion criteria was loss of imaging data. Complications during hospitalisation (early complication) and after discharge (late complication) were compared in groups. Plastic and orthopaedic surgeons performed cosmetic evaluations with the modified Vancouver Scar Scale (VSS) and Likert scale at three and six months postoperatively and compared in groups. RESULTS: A total of 249 arthroplasties (suture group=88 patients; staple group=94 patients; OCA-M group=67 patients) were included in the study. The OCA-M group had a significantly lower early complication rate than the suture group (p=0.015). For THA, the OCA-M group had a significantly lower total complication rate than the suture group (p=0.048). For TKA, there was no significant difference among the three groups. The complication rate in the OCA-M group showed no significant difference between THA/TKA. With regards to the VSS, the OCA-M group was significantly better for cosmetic qualities than the suture group (p=<0.001, p=0.021 at three and six months, respectively). For the Likert scale, the OCA-M group was also significantly better for cosmetic qualities than the suture group and staple group (suture-OCA-M, p=0.003 (three months), p=<0.001 (six months); staple-OCA-M, p=0.027 (three months)). CONCLUSION: In this study, the OCA-M complication rate was low compared to suturing and similar to stapling. Moreover, better cosmetic outcomes were achieved compared to suturing and stapling.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Cianoacrilatos , Humanos , Telas Cirúrgicas , Técnicas de Sutura , Suturas , Poliésteres/uso terapêutico
19.
Sci Rep ; 14(1): 7289, 2024 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-38538657

RESUMO

Iatrogenic stomach perforation is a detrimental, irreversible, and fatal condition. Traditional surgery and endoscopic suturing clips and devices have been introduced to seal holes and prevent sepsis and disease progression. However, the development of endoscopic devices for perforations remains challenging, with no standard device available. This study investigates the superficial layer approximation strengths of the newly designed ENDOCRAB system for gastric wall defects. Thirty porcine stomachs were prepared ex vivo for the perforation model and distributed equally into three groups: ENDOCRAB system, Through-the-Scope Clip (TTSC), and hand suturing (HS). Both ENDOCRAB and TTSC achieved mucosal-submucosal layer apposition, whereas HS allowed a full-thickness layer. Their air leakage pressure and procedural duration were measured. The analysis of air-leakage pressure demonstrated comparable suture strength between ENDOCRAB (118.5 ± 41.7 mmHg) and HS (127.4 ± 30.2 mmHg, P = 0.812), but inferior strength with TTSC (73.6 ± 21.6 mmHg, P = 0.012). HS achieved the shortest procedural duration, whereas ENDOCRAB and TTSC showed no significant differences. The ENDOCRAB system showed significantly greater strength than the TTSC, was comparable to HS in strength, and required a procedural duration similar to that of the TTSC. Furthermore, long-term in vivo experiments and histological evaluations are essential.


Assuntos
Cirurgia Endoscópica por Orifício Natural , Gastropatias , Suínos , Animais , Estômago/cirurgia , Técnicas de Sutura , Instrumentos Cirúrgicos
20.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(3): 267-271, 2024 Mar 15.
Artigo em Chinês | MEDLINE | ID: mdl-38500417

RESUMO

Objective: To investigate the effectiveness of arthroscopic suspension fixation with Endobutton in the treatment of tibial insertion avulsion fractures of posterior cruciate ligament (PCL). Methods: A retrospective analysis was conducted on the clinical data of 52 patients (52 knees) with tibial insertion avulsion fractures of PCL, who were treated by arthroscopic suspension fixation with Endobutton between June 2017 and October 2022. There were 29 males and 23 females, with an average age of 40.6 years (range, 19-66 years). There were 24 cases of traffic accident injuries, 17 cases of sports injuries, and 11 cases of fall injuries. The time from injury to operation ranged from 6 to 19 days (mean, 13.3 days). According to the Meyers-McKeever classification, there were 30 cases of type Ⅱ and 22 cases of type Ⅲ fractures. All patients exhibited positive posterior drawer test results. Preoperative knee joint function was assessed with Lysholm score (21.3±6.7), International Knee Documentation Committee (IKDC) score (20.7±5.8), and visual analogue scale (VAS) score (5.3±0.7); and knee joint range of motion was (41.73±3.17)°. Based on preoperative CT three-dimensional reconstruction measurements, the longitudinal diameter of the avulsed bone fragment ranged from 13 to 25 mm (mean, 18.1 mm). Operation time and occurrence of complications were recorded, and postoperative imaging was used to assess fracture healing. Knee joint function and pain severity were evaluated using knee joint range of motion, Lysholm score, IKDC score, and VAS score. Results: The operation time ranged from 46 to 81 minutes (mean, 56.2 minutes). All patients were followed up 12-28 months (mean, 20.1 months). The iatrogenic fractures of bone fragments occurred during operation in 4 cases; and knee effusion occurred in 2 cases and anterior knee pain in 1 case after operation. All incisions healed by first intention. Imaging evaluations at 3 months after operation showed the fracture healing and no internal fixation failure. All patients demonstrated good knee function and had returned to normal activities at 12 months after operation. At last follow-up, the knee joint range of motion was (133.44±4.17)°, Lysholm score 93.6±3.1, IKDC score 93.4±2.5, and VAS score 1.0±0.6, with significant differences compared to preoperative scores ( P<0.05). Conclusion: Arthroscopic suspension fixation with Endobutton in the treatment of tibial insertion avulsion fractures of PCL is simple to operate, and the knee joint function recovers well.


Assuntos
Lesões do Ligamento Cruzado Anterior , Fratura Avulsão , Ligamento Cruzado Posterior , Fraturas da Tíbia , Masculino , Feminino , Humanos , Adulto , Ligamento Cruzado Posterior/cirurgia , Ligamento Cruzado Posterior/lesões , Ligamento Cruzado Anterior/cirurgia , Fratura Avulsão/cirurgia , Estudos Retrospectivos , Lesões do Ligamento Cruzado Anterior/cirurgia , Resultado do Tratamento , Artroscopia/métodos , Técnicas de Sutura , Articulação do Joelho/cirurgia , Fraturas da Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...